Where a solution anneal and extinguish as a post-weld heat treatment is to be done, ZERON 100 is normally welded with coordinating composition consumables (ZERON 100M). With over alloyed consumables (ZERON 100X), no post-weld heat treatment is essential. In Zeron 100, corrosion and mechanical properties like the parent metal can be acquired after recommended techniques.